| Accuracy class: | class 0.5, class 0.2 |
| Ambient temperature: | -40℃~60℃ |
| Medium temperature: | -20℃~+60℃(High temperature radiator can reach up to 250 ℃). |
| Signal output: | 4-20mA analog signal, pulse signal, RS485, HART, etc. are available for selection. |
| Explosion proof sign: | Exd IIC T6 Gb,Exdb IIC T6 Gb |
| protection grade: | IP66 |
Principle structure:
The LLT series dual rotor flowmeter consists of a flow transmitter and a counter. The main part of the transmitter is a metering device equipped with a pair of special toothed spiral rotors.


The measuring chamber mainly has a sealed cavity composed of a pair of special rotors and cover plates as the measuring unit of flow. The rotor is driven by the pressure difference at the inlet and outlet of the flowmeter to rotate, continuously measuring the liquid at the inlet through the sealing chamber and sending it to the outlet. The amount of liquid flowing through each rotation is eight times that of the sealing chamber shown in the figure. The total number of rotations of the rotor and the speed of rotation are transmitted to the counting mechanism by the sealing coupling, and the pointer display and word wheel accumulation can be used to determine the total amount of liquid passing through the pipeline. In the counting mechanism, a pulse transmitter can also be installed, which becomes a flow meter with a transmitter.
It is matched with our company’s electronic display instrument and can achieve remote transmission (quantitative, cumulative, instantaneous and other functions) for automated measurement and control. Please refer to the classification instructions for display instruments for usage instructions.
Technical Parameter:
1.Accuracy class:0.5、0.2
2.Medium temp:-20℃~+60℃(High temperature radiator can reach up to 250 ℃)
3.Environment temp:
Electronic counter (Std configuration):-30℃~+60℃
Electronic counter (optional):-43℃~+60℃
4.Signal output: selectable from 4 to mA analog signal, pulse signal, RS485, and Hart
5.Ex sign:ExdⅡCT6、ExiaⅡCT6
6.Ingress Protection:IP66
7.Flange Std:GB/T9124.1(Please communicate with the manufacturer for other standards)
8.Repetitive error:The repeatability error of the flow meter shall not exceed one-third of the absolute value of the basic error limit of the flow meter
9.Flow range:m3/h,class 0.5
| Type | DN | Viscosity mPa.s | ||||||
| 0.3~0.8 | 0.8~2 | 2~15 | 15~400 | 400~1000 | 1000~2000 | 2000~3500 | ||
| Gas | Coal oil | Diesel oil | Heavy oil | High viscosity liquid | ||||
| LLT-0252 | 25 | 3~9 | 1.5~10 | 1~10 | 1~10 | 1~8 | 1~8 | 1~6 |
| LLT-0401 | 40 | 3~9 | 1.5~10 | 1~10 | 1~10 | 1~8 | 1~8 | 1~6 |
| LLT-0402 | 7~20 | 3~22 | 2.5~25 | 2.5~25 | 2~18 | 2~18 | 3~12 | |
| LLT-0501 | 50 | 7~20 | 3~22 | 2.5~25 | 2.5~25 | 2~18 | 2~18 | 3~12 |
| LLT-0502 | 9~36 | 4.5~36 | 3.6~36 | 3.6~36 | 2.8~25 | 2.8~25 | 4.5~18 | |
| LLT-0801 | 80 | 9~36 | 4.5~36 | 3.6~36 | 3.6~36 | 2.8~25 | 2.8~25 | 4.5~18 |
| LLT-0802 | 20~100 | 15~110 | 12~120 | 8~120 | 5~65 | 5~47 | 5~40 | |
| LLT-1001 | 100 | 20~100 | 15~110 | 12~120 | 8~120 | 5~65 | 5~47 | 5~40 |
| LLT-1002 | 28~160 | 20~160 | 17~180 | 15~180 | 8~95 | 7~65 | 7~55 | |
| LLT-1501 | 150 | 28~160 | 20~160 | 17~180 | 15~180 | 8~95 | 7~65 | 7~55 |
| LLT-1502 | 50~250 | 40~250 | 30~270 | 20~270 | 12~160 | 10~110 | 8~90 | |
| LLT-2001 | 200 | 50~250 | 40~250 | 30~270 | 20~270 | 12~160 | 10~110 | 8~90 |
| LLT-2002 | 90~360 | 50~400 | 40~400 | 40~400 | 28~240 | 28~240 | 20~160 | |
| LLT-2501 | 250 | 90~360 | 50~400 | 40~400 | 40~400 | 28~240 | 28~240 | 20~160 |
| LLT-2502 | 130~5400 | 65~540 | 60~600 | 60~600 | 42~360 | 42~360 | 30~240 | |
| LLT-3001 | 300 | 130~5400 | 65~540 | 60~600 | 60~600 | 42~360 | 42~360 | 30~240 |
| LLT-3002 | 220~800 | 110~900 | 95~950 | 95~950 | 70~600 | 70~600 | 54~450 | |
| LLT-3501 | 350 | 220~800 | 110~900 | 95~950 | 95~950 | 70~600 | 70~600 | 54~450 |
Flow range:m3/h,class 0.2
| Type | DN | Viscosity mPa.s | ||||||
| 0.3~0.8 | 0.8~2 | 2~15 | 15~400 | 400~1000 | 1000~2000 | 2000~3500 | ||
| Gas | Coal oil | Diesel oil | Heavy oil | High viscosity liquid | ||||
| LLT-0252 | 25 | 3.5~8 | 3~10 | 2~10 | 2~10 | 2~8 | 2~8 | 2~6 |
| LLT-0401 | 40 | 3.5~8 | 3~10 | 2~10 | 2~10 | 2~8 | 2~8 | 2~6 |
| LLT-0402 | 8~20 | 5.5~22 | 4.5~22 | 4.5~22 | 4~18 | 4~18 | 3~12 | |
| LLT-0501 | 50 | 8~20 | 5.5~22 | 4.5~22 | 4.5~22 | 4~18 | 4~18 | 3~12 |
| LLT-0502 | 15~36 | 9~36 | 7~36 | 7~36 | 6~25 | 6~25 | 4.5~18 | |
| LLT-0801 | 80 | 15~36 | 9~36 | 7~36 | 7~36 | 6~25 | 6~25 | 4.5~18 |
| LLT-0802 | 20~80 | 15~80 | 12~100 | 8~100 | 6~55 | 5~40 | 5~35 | |
| LLT-1001 | 100 | 20~80 | 15~80 | 12~100 | 8~100 | 6~55 | 5~40 | 5~35 |
| LLT-1002 | 28~110 | 20~110 | 17~150 | 15~150 | 8~80 | 8~55 | 7~45 | |
| LLT-1501 | 150 | 28~110 | 20~110 | 17~150 | 15~150 | 8~80 | 8~55 | 7~45 |
| LLT-1502 | 50~180 | 40~180 | 30~250 | 20~250 | 12~130 | 12~100 | 12~85 | |
| LLT-2001 | 200 | 50~180 | 40~180 | 30~250 | 20~250 | 12~130 | 12~100 | 12~85 |
| LLT-2002 | 150~360 | 90~360 | 72~360 | 72~360 | 50~210 | 50~210 | 40~160 | |
| LLT-2501 | 250 | 150~360 | 90~360 | 72~360 | 72~360 | 50~210 | 50~210 | 40~160 |
| LLT-2502 | 180~540 | 135~540 | 100~540 | 100~540 | 90~360 | 90~360 | 60~240 | |
| LLT-3001 | 300 | 180~540 | 135~540 | 100~540 | 100~540 | 90~360 | 90~360 | 60~240 |
| LLT-3002 | 250~800 | 220~900 | 180~900 | 180~900 | 150~600 | 150~600 | 110~450 | |
| LLT-3501 | 350 | 250~800 | 220~900 | 180~900 | 180~900 | 150~600 | 150~600 | 110~450 |
Note : accuracy class could be more high for special requirement.
Special instructions:
Mainly for some identification of special products. It is required to appear after the product number to indicate differentiation. Example product number: 1108052 LA.
Indicates that the flowmeter can be installed vertically.
| MI | HG | SH | SM | AS | JS |
| Military industry | Chemical industry | Petrochemical industry | Marine use | American Std | Japanese Std |
Signal Transmission for Liquid Flow Meters:
Reliable Remote Signal Output for Liquid Flow Measurement
Liquid flow meters are widely used in water treatment, chemical dosing, food processing, and industrial pipelines. To meet modern monitoring requirements, liquid flow meters are equipped with multiple signal transmission options for long-distance and real-time data collection.
- 4–20 mA Analog Output: Provides stable and interference-resistant transmission over long distances. Ideal for continuous liquid flow monitoring and integration with PLC and DCS systems.
- Pulse / Frequency Output: Suitable for total flow calculation, batching systems, and water consumption measurement in municipal and industrial applications.
- RS485 with Modbus RTU Protocol: Enables digital communication for accurate remote monitoring. Supports multi-point networking and centralized data acquisition.
- HART Communication (Optional): Allows remote configuration, diagnostics, and calibration without interrupting operation.
Application Value:
- Real-time liquid flow monitoring
- Reduced manual meter reading
- Improved data accuracy and traceability
Automation Capability of Liquid Flow Meters:
Seamless Integration into Automated Liquid Control Systems
Liquid flow meters play a key role in automated process control, especially where precise flow regulation is required.
Fully compatible with PLC systems (Siemens, Schneider, Mitsubishi, Allen-Bradley, etc.)
Supports SCADA and DCS platforms for centralized control and visualization
Enables automatic valve and pump regulation based on real-time flow feedback
Suitable for closed-loop control in dosing, mixing, and filling processes
Automation Benefits:
- Improved process stability
- Reduced operator intervention
- Enhanced production efficiency and repeatability
IoT & Smart Monitoring for Liquid Flow Meters:
Smart Liquid Flow Measurement with IoT Connectivity
IoT-enabled liquid flow meters allow users to monitor liquid flow data anytime and anywhere.
- Wireless Communication Options: NB-IoT, LoRaWAN, Wi-Fi, or Ethernet (depending on configuration)
- Cloud Platform Integration: Flow data is transmitted to cloud servers for real-time access, historical analysis, and reporting.
- Remote Monitoring Dashboard: Displays instant flow rate, cumulative volume, alarm status, and system diagnostics.
- Predictive Maintenance Support: Data analytics help detect abnormal flow patterns, leaks, or blockages early.
IoT Advantages:
- Centralized liquid flow management
- Lower maintenance costs
- Support for smart factories and digital water systems
Welcome to ask us for detailed product manuals.
- Digital dual rotor flowmeter system
- Double Spiral Rotor Flow Meter price
- Efficient dual rotor flowmeter calibration
- Exact Dual Rotor Turbine Flow Meter
- High performance dual rotor flowmeter supplier
- Liquid flow meter for tanks
Tags:
-
Prev : Intelligent Industrial Electromagnitic Flowmeter LDJ Series Solution
-
Next : Precise Metal Scraper Flowmeter Positive Displacement Flowmeter System